HEYI CCT-24 Split-Core CT for a Tesla Solar and Energy Storage Project

Views : 52
Update time : 2026-11-11 09:05:12

The HEYI CCT-24 split-core CT is part of the Tesla Solar and energy storage project. The compact mounting kit measures alternating current on distribution plates and measuring boxes with limited installation space.

 split-core CT

1. Where do solar and storage systems need external CT?

 

1.1 Typical AC measuring points

 

When using a split-core current transformer for solar metering, select a measurement point based on the power flow to follow.

  • Sort AC inverter PV. Monitor production with a separate connected solar indicator.
  • Download the sub-panel. Measure the consumption of the circuits controlled by the sub-panel.
  • Network connection. Monitor network import and export with a bidirectional measuring device.

 

1.2 Example of industrial application of FranklinWH

 

In some installations, the connection of a photovoltaic system or a charging sub-panel via the internal CT aGate prevents the capture of electrical flow. FranklinWH uses its own external split-core CT kit to meter the affected circuits and incorporate those readings into the FHP system. FranklinWH Split CT Kit      

The assembly uses magnetic induction to generate a low-level current signal, with a sensor circuit electrically isolated from the source conductor. Its clamp construction simplifies mounting around existing cables. FranklinWH Split CT Datasheet  

    

2.How does the CCT-24 work in the measuring system?

 

2.1 Magnetic induction and closure assembly

 

A split-core CT uses the changing magnetic field around the alternate conductor to induce a weak signal in its secondary winding. The signal is proportional to the initial current and the sensor circuit remains electrically separate from the conductor. A compatible measuring apparatus connects the CT signal to the corresponding phase voltage for the calculation of power and energy. Housing adjustment simplifies modernization by mounting around an existing insulated cable while the cable remains finished.

 

2.2 CCT-24 Specifications

 

Parameter

CCT-24

Primary current

0–250 A AC

Secondary output

333 mV AC (0.333 V) or 250 mA AC

Accuracy class

Class 0.5

Frequency

50/60 Hz

Aperture diameter

24.6 mm

Operating temperature

−25 °C to +75 °C

 

2.3 Compatibility of measuring instruments and installation space

 

The 333 mV split-core CT uses an integrated precision load resistor. For stand-alone meters and OEM projects, adjust the output and CT ratio to the meter input and parameters. Leave enough space for the clamp to open inside the box.

split-core CT

3. Where Else Can Split-Core CTs Be Used?

 

3.1 Power, Energy and Equipment Monitoring

 

Application

What the Current Readings Support

Power metering

Measure circuit-level power and energy with a compatible meter.

Building submetering

A current transformer for building submetering supports consumption analysis, energy efficiency monitoring and cost allocation by area or tenant.

Power quality monitoring

Provide current data for monitoring distribution equipment when the CT meets the instrument’s bandwidth requirements.

Equipment condition monitoring

Track changes in operating current on conveyors, pumps and other motor-driven equipment.

Hybrid inverters for home energy storage

Pair a split-core CT for home energy storage with a compatible hybrid inverter or external meter to monitor an AC feeder.

Distribute


 split-core CT

4. How to request a price for CCT-24?

 

4.1 Project details for RFQ

 

Send to HEYI the introduction scheme, the model of the meter or converter, the expected alternating current, the outer diameter of the cable, the required power and the estimated amount. We can review the metering point and help you select a CCT-24 split-core CT configuration. heyi@heyiele.com

Compay: WENZHOU HEYI ELECTRICAL CO.,LTD

Brand: HEYI/ASCT

Contact: Bethy

E-mail: heyi@heyiele.com

Tel: 86-13968747975

Related News
Read More >>
HEYI Advances High-Accuracy Split-Core Current Transformers and Eastern European Cooperation HEYI Advances High-Accuracy Split-Core Current Transformers and Eastern European Cooperation
Nov .17.2026
HEYI advances Class 0.5S and Class 0.2 Split-Core CT designs for energy monitoring at low primary current ratios and explores technical cooperation in Eastern Europe.
Outdoor Split-Core CT for Light Rail: Busan-Gimhae Project RFQ Guide Outdoor Split-Core CT for Light Rail: Busan-Gimhae Project RFQ Guide
Nov .09.2026
Explore HEYI’s Outdoor Split-Core CT for Light Rail application in the Busan-Gimhae Light Rail project. Learn how Split-Core CTs are used in AC Distribution Cabinets and what buyers should include in an RFQ.
How Is HEYI Expanding in Central Asia Through PowerExpo Almaty 2026? How Is HEYI Expanding in Central Asia Through PowerExpo Almaty 2026?
Oct .30.2026
HEYI visited PowerExpo Almaty 2026 to explore the Kazakhstan electrical market and learn more about demand for current transformers, current sensing and electrical measurement solutions.
Why Is Your Active Harmonic Filter Underperforming? HEYI CT Guide Why Is Your Active Harmonic Filter Underperforming? HEYI CT Guide
Oct .24.2026
Why is your Active Harmonic Filter underperforming? HEYI explains split-core CT clamp selection, current transformer placement, polarity, and 5A vs. 333mV output compatibility for U.S. 480V systems.