Type B Residual Current Sensors (RCS) are advanced electrical safety devices designed to provide comprehensive protection against various types of electrical faults, including both AC and DC residual currents. They are a critical component of modern electrical systems, especially those involving renewable energy sources and sensitive electronic equipment.
Type B Residual Current Sensors are advanced safety components that offer comprehensive protection against a wide range of residual current faults, including AC, pulsating DC, and smooth DC residual currents. Their high sensitivity, dual-slope detection, and compatibility with diverse electrical systems make them essential for enhancing electrical safety, especially in applications involving renewable energy and sensitive electronic equipment.
| Model | Corresponding standards | DC trigger threshold | AC trigger threshold |
| HYCA-07/MD | IEC62955 | 6mA | / |
|
Electrical data – Ratings: |
||||
|
Action current |
Unit | Min. | Typ | Max. |
|
Operating current S-DC |
mA | 20.0 | 23.0 | 26.0 |
|
Operating current 2PDC |
mA | 11.0 | 15.0 | 30.0 |
|
Operating current 3PDC |
mA | 10.0 | 20.0 | 30.0 |
|
|
||||
|
Operating time |
Unit | Min | Typ | Max |
| Limit values of break time@6mA DC | ms | 100 | 10000 | |
|
Limit values of break time@60mA DC |
ms |
50 | 300 | |
|
Limit values of break time@200mA DC |
ms |
50 | 100 | |
| Limit values of break time@60mA 2PDC | ms |
50 | 300 | |
| Limit values of break time@200mA 2PDC | ms |
50 | 100 | |
| Limit values of break time@60mA 3PDC | ms |
50 | 300 | |
| Limit values of break time@200mA 3PDC | ms |
50 | 100 | |
| No action time | Unit | Min | Typ | LOWER |
| Limit values of break time@30mA AC | ms |
∞ |
∞ | |
| Limit values of break time@60mA AC | ms |
∞ |
300 | |
| Limit values of break time@150mA AC | ms |
∞ |
80 | |
| Limit values of break time@5A AC | ms |
>80 |
80 | |
Dimensions
| Mechanical dimension(for reference only) |
![]() |
Standards
1. What residual current does HYCA-07/MD monitor?
The HYCA-07/MD model table lists a 6 mA DC trigger threshold with no separate AC trigger threshold. It is therefore important to confirm how the finished EV charger provides its AC residual-current protection and fault disconnection.
2. Is HYCA-07/MD relevant to IEC 62955 Mode 3 EV charging?
The published HYCA-07/MD table references IEC 62955, which addresses residual direct current detecting devices for Mode 3 AC charging. The final RDC-DD configuration and complete EV charger must be assessed against the applicable standard requirements.
3. How does HYCA-07/MD differ from HYCA-07/PD?
HYCA-07/MD is listed with a 6 mA DC threshold, while HYCA-07/PD lists both 6 mA DC and 30 mA AC. Select the version after defining your charger protection circuit, required output signals and any separate RCD or contactor.
4. Can HYCA-07/MD connect directly to an EV charger control board?
Integration depends on the board supply, interface levels, connector pinout and fault-response logic. Send HEYI your controller schematic or interface requirements to confirm the correct HYCA-07/MD version and latest wiring information.
5. What should be included in an HYCA-07/MD validation plan?
Test the required smooth DC and pulsating DC residual-current conditions, sensor response time and behavior during start-up or power faults. System-level testing should also verify that the charger opens the circuit as required by its protection design.