HYCA-01 is residual current operated protective sensor for EV charger.It’s to avoid hazardous situations in cases where the vehicle battery (DC) is connected to the home power supply (AC). Generally, AC/DC sensitive residual current sensors can be used where direct current and alternating current and alternating current circuits are directly connected and therefore AC/DC leakage currents can occur.
| Electrical/Reliability Characteristics | |
| Working Temperature | -40℃~85℃ |
| Storage Temparature | -40℃~65℃ |
| Supply Voltage(VDD) | 4.85~5.15 VDC recommend 4.9-5.1 VDC |
| Static Power Consumption | 110mW |
| Clearance (Primary-Primary/Secondary) |
≥6.5mm ≥10mm |
| Creepage Primary-Primary/Secondary) |
≥8mm ≥10mm |
| Voltage Input, low level | 0~0.6VDC |
| Voltage Input, high level | 4.2~5VDC |
| Designed Life | ≥20 years |
| Working Altitude | ≤4000m |
|
Electrical data – Ratings: |
||||
|
Action current |
Unit | Min. | Typ | Max. |
|
Operating current S-DC |
mA | 20.0 | 23.0 | 26.0 |
|
Operating current 2PDC |
mA | 11.0 | 15.0 | 30.0 |
|
Operating current 3PDC |
mA | 10.0 | 20.0 | 30.0 |
|
|
||||
|
Operating time |
Unit | Min | Typ | Max |
| Limit values of break time@6mA DC | ms | 100 | 10000 | |
|
Limit values of break time@60mA DC |
ms |
50 | 300 | |
|
Limit values of break time@200mA DC |
ms |
50 | 100 | |
| Limit values of break time@60mA 2PDC | ms |
50 | 300 | |
| Limit values of break time@200mA 2PDC | ms |
50 | 100 | |
| Limit values of break time@60mA 3PDC | ms |
50 | 300 | |
| Limit values of break time@200mA 3PDC | ms |
50 | 100 | |
| No action time | Unit | Min | Typ | LOWER |
| Limit values of break time@30mA AC | ms |
∞ |
∞ | |
| Limit values of break time@60mA AC | ms |
∞ |
300 | |
| Limit values of break time@150mA AC | ms |
∞ |
80 | |
| Limit values of break time@5A AC | ms |
>80 |
80 | |
Dimensions
| Mechanical dimension(for reference only) | Note |
![]() |
![]() |
Standards
UL94-V0.
EN60947-1:2004
IEC60950-1:2001
EN50178:1998
SJ 20790-2000
1. Is HYCA-05 intended for DC residual current detection?
The HYCA-05 product heading identifies a 6 mA DC residual current sensor for EV charging. However, the detailed operating-current table on the current page needs confirmation against the latest datasheet. Request the validated trigger range before selecting it for a protection circuit.
2. Does HYCA-05 also provide a 30 mA AC trip function?
The HYCA-05 page does not clearly establish a separate 30 mA AC protective output. If your charger requires AC and DC residual-current protection, submit your protection scheme so HEYI can confirm whether HYCA-05 is sufficient or recommend an appropriate dual-function variant.
3. What power supply is specified for HYCA-05?
The published electrical data lists a 4.85–5.15 V DC supply range and recommends 4.9–5.1 V DC. Verify the current device drawing, connector orientation and output levels before finalizing an OEM controller design.
4. Can HYCA-05 be used in portable and wall-mounted EV chargers?
The product page lists portable Mode 2 chargers and Mode 3 AC wallboxes as potential applications. Final suitability depends on the chosen protection architecture, controller interface, applicable standard and validated residual-current response.
5. What should be checked before ordering HYCA-05 evaluation samples?
Confirm the exact model revision, DC trigger threshold, expected response time, available installation space and output connector. HEYI can discuss paid samples for OEM testing after the electrical requirements and quantities are provided.


Tel:13968747975
E-mail: bethy@heyiele.com
Add:(Zhejiang Lierde Relay Co., Ltd.) Xinguang Ind. Zone, Liushi Town, Wenzhou, Zhejiang, China