Residual current device sensor (RCDs) or residual current sensors are indispensable safety components used to protect against electrical and ground faults in a variety of applications. Their high sensitivity, fast tripping mechanisms and compatibility with a variety of electrical systems make them vital for ensuring electrical safety in residential and industrial environments and preventing accidents and damage.
Standards and Regulations:
Residual current device sensor are subject to various national and international standards and regulations that define their installation requirements and performance standards. HYCA-F03 complies with IEC62752, IEC62955, UL2231 standards.
| Model | Corresponding standards | DC trigger threshold | AC trigger threshold |
| HYCA-03/PD | IEC62752 | 6mA | 30mA |
| Electrical/Reliability Characteristics | |
| Working Temperature | -40℃~85℃ |
| Storage Temparature | -20℃~65℃ |
| Supply Voltage(VDD) | 4.85~5.15 VDC recommend 4.9-5.1 VDC |
| Static Power Consumption | 110mW |
| Clearance (Primary-Primary/Secondary) |
≥6.5mm ≥10mm |
| Creepage Primary-Primary/Secondary) |
≥8mm ≥10mm |
| Voltage Input, low level | 0~0.6VDC |
| Voltage Input, high level | 4.2~5VDC |
| Designed Life | ≥20 years |
| Working Altitude | ≤4000m |
| Trip-Current (residual current related characteristics. | |||||
| Wav. | Freq. | Min. | Typ | Max. | Unit |
| AC | 50Hz | 20.0 | 23.0 | 26.0 | mA |
| A0° | 50Hz | 11.0 | 15.0 | 30.0 | mA |
| A90° | 50Hz | 10.0 | 20.0 | 30.0 | mA |
| A135° | 50Hz | 10.0 | 24.0 | 35.0 | mA |
| 2PDC | 50Hz | 3.5 | 5.0 | 7.0 | mA |
| 3PDC | 50Hz | 3.1 | 4.6 | 6.2 | mA |
| S-DC | – | 3.0 | 4.6 | 6.0 | mA |
| Trip-Time (residual current related characteristics | ||||
| Wav. | Freq. | Current | TYP. | Unit |
| AC | 50Hz | 30mA | 25 | ms |
| AC | 50Hz | 60mA | 16 | ms |
| AC | 50Hz | 150mA | 15 | ms |
| AC | 50Hz | 5A~100A | 8.5 | ms |
| A0° | 50Hz | 42mA | 25 | ms |
| A0° | 50Hz | 84mA | 18 | ms |
| A0° | 50Hz | 210mA | 10 | ms |
| A0° | 50Hz | 42mA+6mADC | 18 | ms |
| A0° | 50Hz | 84mA+6mADC | 15 | ms |
| A0° | 50Hz | 210mA+6mADC | 15 | ms |
| S-DC | 6mA | 48 | ms | |
| S-DC | 60mA | 16 | ms | |
| S-DC | 300mA | 8.5 | ms | |
| 2PDC/3PDC | 50Hz | 60mA | 20 | ms |
| 2PDC/3PDC | 50Hz | 120mA | 25 | ms |
| 2PDC/3PDC | 50Hz | 300mA | 12 | ms |
| 2PDC/3PDC | 50Hz | 5~50A | 12 | ms |
Dimensions
| Mechanical dimension(for reference only) |
![]() |
Standards
IEC62752
IEC62955
UL2231
1. Does HYCA-03/PD detect both 6 mA DC and 30 mA AC leakage?
Yes. The HYCA-03/PD product table lists a 6 mA DC trigger threshold and a 30 mA AC trigger threshold. The exact operating bands and response times depend on the residual-current waveform, so use the model-specific datasheet for the full protection design.
2. Can HYCA-03/PD be used in Mode 2 portable EV chargers?
The page lists IEC 62752 among the related test requirements and identifies portable Mode 2 charging equipment as an application. The complete IC-CPD must meet all applicable system-level requirements; a sensor alone is not a complete protective switching device.
3. What supply voltage does HYCA-03/PD need?
The published HYCA-03/PD electrical characteristics specify 4.85–5.15 V DC. Before finalizing a printed circuit board, request the latest connector drawing and verify signal logic, pin assignment, start-up behavior and tolerance with HEYI.
4. How should HYCA-03/PD be connected to an EV charger controller?
The sensor should be integrated according to its model-specific wiring diagram. All current-carrying conductors of the monitored circuit must be considered in the sensing arrangement. The controller and switching components must be designed and tested to respond to the required fault signals.
5. Can HEYI provide HYCA-03/PD samples for design validation?
HEYI can discuss paid evaluation samples and provide the current datasheet and mechanical information for review. Please specify the charger type, intended market, required test standard and expected production quantity so the correct configuration can be confirmed.


Tel:13968747975
E-mail: bethy@heyiele.com
Add:(Zhejiang Lierde Relay Co., Ltd.) Xinguang Ind. Zone, Liushi Town, Wenzhou, Zhejiang, China