HYCA-01 is residual current operated protective sensor for EV charger.It’s to avoid hazardous situations in cases where the vehicle battery (DC) is connected to the home power supply (AC). Generally, AC/DC sensitive residual current sensors can be used where direct current and alternating current and alternating current circuits are directly connected and therefore AC/DC leakage currents can occur.
| Electrical/Reliability Characteristics | |
| Working Temperature | -40℃~85℃ |
| Storage Temparature | -20℃~65℃ |
| Supply Voltage(VDD) | 4.85~5.15 VDC recommend 4.9-5.1 VDC |
| Static Power Consumption | 110mW |
| Clearance (Primary-Primary/Secondary) |
≥6.5mm ≥10mm |
| Creepage Primary-Primary/Secondary) |
≥8mm ≥10mm |
| Voltage Input, low level | 0~0.6VDC |
| Voltage Input, high level | 4.2~5VDC |
| Designed Life | ≥20 years |
| Working Altitude | ≤4000m |
| Trip-Current (residual current related characteristics. | |||||
| Wav. | Freq. | Min. | Typ | Max. | Unit |
| AC | 50Hz | 15 | 17.8 | 20 | mA |
| A0° | 50Hz | 11 | 17 | 26 | mA |
| A90° | 50Hz | 10.0 | 18.5 | 27 | mA |
| A135° | 50Hz | 10.0 | 22.9 | 35 | mA |
| 2PDC | 50Hz | 3.5 | 5.1 | 7 | mA |
| 3PDC | 50Hz | 3.1 | 4.6 | 6.2 | mA |
| S-DC | – | 3.0 | 4.6 | 6.0 | mA |
| Trip-Time (residual current related characteristics | ||||
| Wav. | Freq. | Current | TYP. | Unit |
| AC | 50Hz | 30mA | 110 | ms |
| AC | 50Hz | 60mA | 41 | ms |
| AC | 50Hz | 150mA | 15 | ms |
| AC | 50Hz | 5A~100A | 8.5 | ms |
| A0° | 50Hz | 42mA | 40 | ms |
| A0° | 50Hz | 84mA | 18 | ms |
| A0° | 50Hz | 210mA | 10 | ms |
| A0° | 50Hz | 42mA+6mADC | 18 | ms |
| A0° | 50Hz | 84mA+6mADC | 15 | ms |
| A0° | 50Hz | 210mA+6mADC | 15 | ms |
| S-DC | 6mA | 137 | ms | |
| S-DC | 60mA | 38 | ms | |
| S-DC | 300mA | 8.5 | ms | |
| 2PDC/3PDC | 50Hz | 60mA | 38 | ms |
| 2PDC/3PDC | 50Hz | 120mA | 20 | ms |
| 2PDC/3PDC | 50Hz | 300mA | 8.5 | ms |
| 2PDC/3PDC | 50Hz | 5~50A | 8.5 | ms |
Dimensions
| Mechanical dimension(for reference only) | Note |
![]() |
![]() |
Standards
UL94-V0.
EN60947-1:2004
IEC60950-1:2001
EN50178:1998
SJ 20790-2000
FAQ
1.What is the AC residual current threshold of HYCA-02?
HYCA-02 is identified on the product page as a 6 mA DC and 20 mA AC residual current sensor. Its published 50 Hz sinusoidal AC operating-current range is 15–20 mA. Confirm whether these values match the protection requirements for your charging equipment.
2. How is HYCA-02 different from HYCA-01?
Both models list 6 mA DC detection. The product headings identify a 20 mA AC threshold for HYCA-02 and a 30 mA AC threshold for HYCA-01. Other factors, including response time and approved application, should be compared against both current datasheets before substitution.
3. Can HYCA-02 be considered for North American EV charging equipment?
The HYCA-02 page mentions American-standard EV charging applications. However, the suitability of a sensor for a particular North American project depends on the complete protection architecture, applicable UL requirements and model-specific test evidence. Request the relevant reports before approving a design.
4. Does HYCA-02 require a 5 V DC supply?
The published electrical characteristics specify 4.85–5.15 V DC as the supply range, with 4.9–5.1 V DC recommended. Check the exact pinout, control signal levels and power supply tolerances in the latest HYCA-02 technical drawing.
5. What test information is useful when evaluating HYCA-02?
For an OEM evaluation, compare operating current and response time for sinusoidal AC, pulsating DC and smooth DC leakage, including mixed-waveform conditions where relevant. Ask HEYI for the matching datasheet revision and available test documents for your proposed charging system.