HYCA-01 is residual current operated protective sensor for EV charger.It’s to avoid hazardous situations in cases where the vehicle battery (DC) is connected to the home power supply (AC). Generally, AC/DC sensitive residual current sensors can be used where direct current and alternating current and alternating current circuits are directly connected and therefore AC/DC leakage currents can occur.
| Electrical/Reliability Characteristics | |
| Working Temperature | -40℃~85℃ |
| Storage Temparature | -20℃~65℃ |
| Supply Voltage(VDD) | 4.85~5.15 VDC recommend 4.9-5.1 VDC |
| Static Power Consumption | 110mW |
| Clearance (Primary-Primary/Secondary) |
≥6.5mm ≥10mm |
| Creepage Primary-Primary/Secondary) |
≥8mm ≥10mm |
| Voltage Input, low level | 0~0.6VDC |
| Voltage Input, high level | 4.2~5VDC |
| Designed Life | ≥20 years |
| Working Altitude | ≤4000m |
| Trip-Current (residual current related characteristics. | |||||
| Wav. | Freq. | Min. | Typ | Max. | Unit |
| AC | 50Hz | 20.0 | 23.0 | 26.0 | mA |
| A0° | 50Hz | 11.0 | 15.0 | 30.0 | mA |
| A90° | 50Hz | 10.0 | 20.0 | 30.0 | mA |
| A135° | 50Hz | 10.0 | 24.0 | 35.0 | mA |
| 2PDC | 50Hz | 3.5 | 5.0 | 7.0 | mA |
| 3PDC | 50Hz | 3.1 | 4.6 | 6.2 | mA |
| S-DC | – | 3.0 | 4.6 | 6.0 | mA |
| Trip-Time (residual current related characteristics | ||||
| Wav. | Freq. | Current | TYP. | Unit |
| AC | 50Hz | 30mA | 25 | ms |
| AC | 50Hz | 60mA | 16 | ms |
| AC | 50Hz | 150mA | 15 | ms |
| AC | 50Hz | 5A~100A | 8.5 | ms |
| A0° | 50Hz | 42mA | 25 | ms |
| A0° | 50Hz | 84mA | 18 | ms |
| A0° | 50Hz | 210mA | 10 | ms |
| A0° | 50Hz | 42mA+6mADC | 18 | ms |
| A0° | 50Hz | 84mA+6mADC | 15 | ms |
| A0° | 50Hz | 210mA+6mADC | 15 | ms |
| S-DC | 6mA | 48 | ms | |
| S-DC | 60mA | 16 | ms | |
| S-DC | 300mA | 8.5 | ms | |
| 2PDC/3PDC | 50Hz | 60mA | 20 | ms |
| 2PDC/3PDC | 50Hz | 120mA | 25 | ms |
| 2PDC/3PDC | 50Hz | 300mA | 12 | ms |
| 2PDC/3PDC | 50Hz | 5~50A | 12 | ms |
Dimensions
| Mechanical dimension(for reference only) | Note |
![]() |
![]() |
Standards
UL94-V0.
EN60947-1:2004
IEC60950-1:2001
EN50178:1998
SJ 20790-200
FAQ
1. What residual current thresholds does the HYCA-01 sensor support?
The HYCA-01 is listed for 6 mA DC and 30 mA AC residual current protection applications. Its datasheet provides separate operating-current and response-time values for different AC and DC waveforms. Confirm the complete charging-system protection design against the applicable standard.
2.Is HYCA-01 suitable for portable EV chargers and AC wallboxes?
HYCA-01 is intended for EV charging equipment, including portable Mode 2 chargers and Mode 3 AC wallboxes. Selection depends on the required residual-current functions, conductor arrangement, protective switching circuit and the standard applicable to the finished charger.
3.What power supply is required for HYCA-01?
The published operating supply range is 4.85–5.15 V DC, with 4.9–5.1 V DC recommended. Verify the connector, output logic and power-up behavior using the current HYCA-01 datasheet before connecting the sensor to the charger control board.
4.How quickly does HYCA-01 respond to a 6 mA DC residual current?
The product page gives a typical sensor response time of 48 ms at 6 mA smooth DC. This is a typical value under the stated test conditions, not a guaranteed total disconnection time for the EV charger. The controller and switching device must also be evaluated.
5.What information should an OEM provide to integrate HYCA-01?
Please share the charger mode, maximum operating current, AC supply configuration, control-board voltage, required output interface, available space and target certification market. HEYI can use these details to check mechanical and electrical compatibility and prepare a quotation.


Tel:13968747975
E-mail: bethy@heyiele.com
Add:(Zhejiang Lierde Relay Co., Ltd.) Xinguang Ind. Zone, Liushi Town, Wenzhou, Zhejiang, China